Coal & Biomass Analysis Instruments

Nine product families covering proximate, ultimate, calorific and fusibility analysis. Each product page states its declared standards with the standard title and whether it is declared or equivalent, a parameter table with explicit units, and the method questions buyers ask before a tender. Send your sample type and required method for confirmation.

Find the instrument for your test

Filter by the sample your plant handles and by the parameter you must report. Counts are live from the catalogue below.

By application
By parameter you must report

9 instruments match: RI-MAC67, RI-C5800, RI-S320, RI-DFS220, RI-IRS3600, RI-CHN2200, RI-AF1600, RI-MW2200, RI-MF1200

  • RI-MAC67Automatic Proximate Analyzer (TGA)
  • RI-C5800Automatic Bomb Calorimeter
  • RI-S320Automatic Horizontal Coulometric Sulfur Analyzer
  • RI-DFS220Robotic Coulometric Sulfur Analyzer
  • RI-IRS3600Automatic Infrared Sulfur Analyzer
  • RI-CHN2200CHN Elemental Analyzer
  • RI-AF1600Ash Fusion Determinator (AFDT)
  • RI-MW2200Automatic Moisture Analyzer
  • RI-MF1200Programmable Muffle Furnace

Model Selection Guide

Nine instruments, five different jobs — find the right one in one page

Our analyzers are not interchangeable. Use Section 1 to find the instrument for the test you need, Section 2 to compare models within the same function, and Section 3 to assemble a lab package for your application.

3. Assemble a package by application

Application Typical configuration
Coal-fired power plant — incoming coal & settlementRI-MAC67 + RI-C5800 + RI-IRS3600 (or RI-S320) + RI-MW2200
Coal mine / wash plant — pit-head controlRI-MW2200 + RI-MAC67 + RI-IRS3600
Commercial testing lab — high throughputRI-DFS220 + dual RI-C5800 + RI-CHN2200
Boiler / slagging & gasifier assessmentRI-AF1600 + RI-MAC67 + RI-C5800
Universities & researchRI-MF1200 + RI-CHN2200 + RI-MW2200
Trade arbitration labRI-S320 (coulometric) + RI-MW2200 (N₂ purge) + RI-AF1600

1. Find the instrument by test

What you need to measure Method / standard Instrument(s)
Moisture (M)GB/T 211, GB/T 212RI-MAC67 (in the proximate run) · RI-MW2200 (dedicated total moisture)
Ash (A)GB/T 212, ASTM D3174RI-MAC67 · RI-MF1200 (manual / backup)
Volatile matter (V)GB/T 212, ASTM D7582RI-MAC67
Fixed carbon (FC)by calculationRI-MAC67
Gross calorific value (Q)ISO 1928, ASTM D5865, GB/T 213RI-C5800
Total sulfur (S)GB/T 214, ISO 16994, ASTM D4239RI-S320 · RI-DFS220 (coulometric) · RI-IRS3600 (infrared)
Carbon / Hydrogen / NitrogenASTM D5373, GB/T 30733RI-CHN2200
Ash fusion temperatures (DT/ST/HT/FT)GB/T 219, ISO 540RI-AF1600
Ashing / ignition loss / fusion prepGB/T 212, ASTM D3174RI-MF1200

2. Compare within each function

2.1 Proximate & ultimate analysis

RI-MAC67 RI-MW2200 RI-CHN2200
MeasuresM, A, V, FCTotal moisture (M)C, H, N
Samples per run202236 (arbitrary insert)
Time90–120 min / 20 samplesClassic 25–45 min · Fast 15–25 min~300 s / sample
Key specification±1 °C, 0.0001 g, dual furnaceLight-wave heating, optional N₂ purgeC ≤0.5 %, H ≤0.15 %, N ≤0.08 %
StandardsASTM D7582, GB/T 212GB/T 211, GB/T 212, GB/T 483ASTM D5373, GB/T 30733
PowerUnit I ≤4 kW · Unit II ≤5 kW<2.5 kW≤4 kW
Best forFull proximate suite, unattendedHigh-volume dedicated moistureUltimate analysis / research

2.2 Calorific value

RI-C5800
MeasuresGross calorific value
Test time≤11 min (fast) · ≤16 min (classic)
PrecisionRSD ≤0.15 %; heat-capacity drift ≤0.20 % / year
StandardsISO 1928, ASTM D5865, GB/T 213, BS EN 15400
ConfigurationSingle or dual control on one controller
Best forTrade settlement, power plants, biomass

2.3 Sulfur analysis — choose by throughput and sample matrix

RI-S320 RI-DFS220 RI-IRS3600
MethodCoulometricCoulometric + robot armInfrared
Samples per run2025 + unlimited top-up24 (cycle loading)
Time per sample3–5 min3–5 min~120 s
Range0.01–40 %0.01–40 %0.01–20 % (extendable)
AutomationAutomatic pusherFull robotic walk-away, auto WO₃ dosingAutomatic weighing & feeding
Maintenance focusElectrolyte / electrodesElectrolyte / electrodesOptical & gas-path checks
StandardsGB/T 214, ISO 16994GB/T 214, ISO 16994GB/T 25214, ASTM D4239 (equiv.)
Best forHigh-sulfur / complex matrix, arbitrationHigh-throughput unattended labsHigh-throughput routine low/mid sulfur

Rule of thumb. Mostly routine low/mid-sulfur samples at high volume → evaluate infrared (RI-IRS3600) first. Frequent high-sulfur or difficult matrices → coulometric (RI-S320 / RI-DFS220). Mixed workloads may justify both methods, subject to sample-method verification.

2.4 Ash fusion & furnaces

RI-AF1600 RI-MF1200
PurposeAsh fusion DT/ST/HT/FTManual ashing / ignition loss / fusion prep
Max temperature1600 °C1200 °C
Samples per run1–5—
Accuracy±1 °C; T1 ≤40 °C, T2–T4 ≤30 °C±1 °C
Key featureCCD auto-recognition + video replayProgrammable PID, safety interlocks
StandardsGB/T 219, ISO 540GB/T 212, ASTM D3174
Best forBoiler slagging, gasifier feed, arbitrationBackup / manual method beside analyzers

These are planning templates, not fixed bundles — final scope depends on sample types, throughput, methods, utilities and local acceptance requirements. Confirm the configuration with an engineer: service@royintelli.com.