RoyIntelli

Coal laboratory instruments · Changsha, China

Coal & Biomass Lab Analyzers, Built on a Real Production Line

Proximate analyzers, bomb calorimeters, sulfur analyzers, CHN elemental analyzers and ash fusion determinators — with model pages organized for technical comparison, supplier prequalification and RFQ review.

  • Standards listed by model
  • Trade terms stated in writing
  • Evidence pack available on request

Inside the factory

Workshop overview: white instrument housings staged on benches at the Changsha production site

Published workshop photographs from our Changsha production site. Request model-specific factory and acceptance evidence before purchase.

9

Product models with buyer datasheets

3

Decision stages covered: method, evidence, RFQ

1

Direct contact for technical review

Open

Evidence pack request process

Product Line

A Complete Coal Quality Lab, One Supplier

From sample preparation to final report — every instrument below runs GB, ISO and ASTM methods, with LIMS connectivity as standard.

RI-MAC67

Automatic Proximate Analyzer (TGA)

Fully automatic thermogravimetric analyzer for moisture, ash, volatile matter and fixed carbon — 20 samples in 90–120 minutes, unattended.

Learn more

RI-C5800

Automatic Bomb Calorimeter

Isoperibol oxygen-bomb calorimeter with automatic oxygen filling, lifting and jacket control. ≤11 min fast mode, RSD ≤0.15 %.

Learn more

RI-S320

Automatic Horizontal Coulometric Sulfur Analyzer

Coulometric titration total-sulfur analyzer, 20-position autosampler, 3–5 min per sample, range 0.01–40 %.

Learn more

RI-DFS220

Robotic Coulometric Sulfur Analyzer

Robot-arm coulometric sulfur analyzer — 25 samples with unlimited top-up, automatic WO₃ dosing, true walk-away operation.

Learn more

RI-IRS3600

Automatic Infrared Sulfur Analyzer

24-position IR sulfur analyzer with automatic weighing and feeding — ~120 s per sample, range 0.01–20 %.

Learn more

RI-CHN2200

CHN Elemental Analyzer

Carbon, hydrogen and nitrogen in ~300 s: IR detection for C/H, thermal conductivity for N. 36-position autosampler with cycle loading.

Learn more

RI-AF1600

Ash Fusion Determinator (AFDT)

Automatic ash fusion determinator with CCD image recognition — DT/ST/HT/FT to 1600 °C, ±1 °C, video replay of every run.

Learn more

RI-MW2200

Automatic Moisture Analyzer

22-position total-moisture analyzer with light-wave heating and optional nitrogen purge — 15–25 min fast mode, 15 % energy saving.

Learn more

RI-MF1200

Programmable Muffle Furnace

Laboratory box furnace to 1200 °C with programmable PID control, uniform chamber and double over-temperature protection.

Learn more

Why RoyIntelli

Factory-Direct, Engineer-Backed

Factory evidence

Review workshop photographs and request model-specific production, quality and acceptance records.

Methods by model

Each product page lists its stated GB/T, ISO or ASTM methods and the questions to confirm before ordering.

Procurement-ready

Download a datasheet without an email gate, then request the documents needed for supplier prequalification.

Direct RFQ

Send the model, sample type, throughput, destination and required evidence for a written configuration review.

How to Order

From Inquiry to Installation in 4 Steps

  1. 01

    Confirm the method

    Choose the model by sample type, standard, range, throughput and acceptance criteria.

  2. 02

    Prequalify the supplier

    Request the factory, certificate, CRM, application and export evidence relevant to your tender — or, for partners, pass training and approval first.

  3. 03

    Compare the RFQ

    Confirm voltage, scope, delivery, payment, warranty and spare-parts terms in writing.

  4. 04

    Accept and support

    Agree the factory/site acceptance record, training scope and post-delivery contact before payment.

Guides

Buying Guides from Our Engineers

All articles →

Bomb Calorimeter Daily Calibration and Operation Checklist

A method-led checklist for daily checks, heat-capacity calibration records, quality control and safe operation of oxygen-bomb calorimeters.

How to Choose an Automatic Proximate Analyzer for a Commercial Coal Lab

Throughput, standard compliance and weighing architecture decide whether a TGA proximate analyzer can survive a commercial lab's arbitration workload. A practical buying guide.

ISO 1928 Bomb Calorimetry: Getting Arbitration-Grade Results Every Time

Benzoic acid traceability, water dosing repeatability and bomb maintenance — the three levers that decide whether your gross calorific values survive a dispute.

Coulometric vs Infrared Sulfur Analyzers: Which Fits Your Lab?

Both measure total sulfur to 0.001 % resolution — but reagent cost, throughput and sample matrix decide which belongs on your bench.

Automatic Proximate Analyzer Buying Guide: Selection, Standards and Test Method

A procurement checklist for comparing TGA proximate analyzers by sample throughput, atmosphere control, weighing traceability and method verification.

Bomb Calorimeter Buying Guide: How to Verify ISO 1928 Results

Compare oxygen-bomb calorimeters by calibration traceability, water dosing, bomb materials, sample matrix and repeatability—not headline test time alone.

Coulometric Sulfur Analyzer Guide: Method Fit, Reagents and Acceptance Tests

How to buy a coulometric sulfur analyzer for coal, coke or oil while controlling combustion completeness, electrolyte service and CRM verification.

Robotic Sulfur Analyzer Buying Guide: Throughput, Loading and Method Control

A practical checklist for deciding whether robotic sample handling actually improves sulfur-lab capacity and traceability.

Infrared Sulfur Analyzer Guide: Calibration, Matrix Effects and Throughput

What to check when comparing infrared combustion sulfur analyzers for routine coal, coke and biomass screening.

CHN Elemental Analyzer Guide: Sample Matrix, Gas Path and Validation

A buyer-side framework for selecting a carbon, hydrogen and nitrogen analyzer and validating its combustion and detector chain.

Ash Fusion Determinator Guide: Temperatures, Atmosphere and Image Review

How to specify an ash-fusion system for deformation, softening, hemispherical and flow temperatures with defensible image records.

Automatic Moisture Analyzer Guide: Sample Preparation and Method Control

Compare automatic moisture analyzers by temperature control, weighing stability, sample handling and the moisture method your lab must defend.

Muffle Furnace Buying Guide: Temperature Uniformity, Safety and Test Method

The procurement checks that matter for a programmable laboratory muffle furnace used for ash, loss-on-ignition and heat-treatment work.

Coal Laboratory Tender Prequalification: The Document Checklist Buyers and Distributors Actually Need

A tender-ready checklist for coal and solid-fuel laboratory instruments: authorization letters, technical and commercial responsibility, acceptance tests, training records and the clauses that most often disqualify a bid.

Becoming an Authorized Partner for Coal Analysis Instruments: What the Program Includes and What It Does Not

How distributor authorization, remote engineer training and certificate levels work for coal and solid-fuel laboratory instruments — and the limits of an authorization letter a buyer should understand.

Customs and Metrology Laboratories: What a Coal Analysis Instrument Purchase Actually Requires

Import verification and reference-laboratory work put calibration traceability, repeatability evidence and document packs ahead of price — a procurement guide for public-sector coal laboratories.

Equipping a Third-Party Coal Testing Laboratory: Throughput, Dual-Method Sulfur and Audit-Ready Training

How independent coal testing laboratories specify instrument capacity, why coulometric and infrared sulfur often coexist, and what auditors examine when a commercial lab buys new equipment.

Need a lab layout & quotation?

Send your sample type and throughput for an instrument recommendation and quotation review.

Get My Quotation